Nov 30 2014 explore alex radford foster s board parapet detail on pinterest.
Parapet wall concrete gutter detail.
Mansard detail lead cad pdf cad dwg.
Gutter with coated metal edge.
Ct 06 base flashing wall cover on wood parapet wall.
The window door and wall penetration details are based on those prepared for c m h c by mr.
The balloon framed steel stud parapet this is the ugliest parapet to get right.
The outlets of overflows should be in a readily visible location so that it is immediately obvious to the occupants that the primary drainage system has failed.
High temperature stack flashing.
Overflows might consist of a second pipe set slightly above the normal down pipe or cut outs at the end of the box gutter that allow water to overflow through the parapet wall.
Metal coping termination cad pdf cad dwg.
5001 m drop inlets for use in front of r e.
Ct 07 concrete or masonry wall base flashing with a 5 course flashing system not suitable for stucco wall assemblies pdf.
Concrete curb and gutter concrete curbs concrete medians.
Wind resistant offset gutter detail drawing dxf 137 17 kb wind resistant offset gutter detail drawing pdf 44 89 kb coping systems.
The masonry parapet the thing to note here is that the concrete deck is the air control layer so an additional one is not necessary.
Mansard detail drip trim cad pdf cad dwg.
Tpa 221 through wall scupper isometric tpa 222 gravel stop scupper detail tpa 232 gutter detail tpa 301 parapet wall flashing detail 8 4 9.
Pipe seal pre fabricated cad pdf cad dwg.
Jim posey of posey construction specifications.
Parapet drain cad pdf cad dwg.
Parapet trim trim with ps tape cad pdf cad dwg.
Standards drainage guardrail barriers roadway sections.
Standards barriers foundations guardrail barriers retaining walls.
Detailed drawings single ply tpa 303 insulated parapet wall flashing detail tpa 304 high parapet wall flashing detail tpa 305 parapet wall flashing detail tpa 310 wall counterflashing detail 8 4 10.
Cmri would like to especially acknowledge masonry canada and the federal.
Detail 1 7 brick veneer concrete block detail of low parapet with protected membrane.
However joints in the concrete deck need to be addressed for air control layer continuity.
High wall flashing detail 10 ft sheet.
Notice the use.
High wall flashing detail intermittent fastening.
Standard modified bitumen and bur details.
Field fabricated wall expansion joint detail curb type.
Type m 1 and m 3 modified std.
Conductor head detail drawing dwg 1 06 mb.
Permaspan roof to wall detail drawing pdf 39 38 kb water control.
High wall flashing detail 5 ft sheet.
Parapet retaining wall types p1 p2 and p3.